Next: Blackfin Directives, Previous: Blackfin Options, Up: Blackfin-Dependent [Contents][Index]
Special Characters
Assembler input is free format and may appear anywhere on the line. One instruction may extend across multiple lines or more than one instruction may appear on the same line. White space (space, tab, comments or newline) may appear anywhere between tokens. A token must not have embedded spaces. Tokens include numbers, register names, keywords, user identifiers, and also some multicharacter special symbols like "+=", "/*" or "||".
Comments are introduced by the ‘#’ character and extend to the end of the current line. If the ‘#’ appears as the first character of a line, the whole line is treated as a comment, but in this case the line can also be a logical line number directive (see Comments) or a preprocessor control command (see Preprocessing).
Instruction Delimiting
A semicolon must terminate every instruction. Sometimes a complete instruction will consist of more than one operation. There are two cases where this occurs. The first is when two general operations are combined. Normally a comma separates the different parts, as in
a0= r3.h * r2.l, a1 = r3.l * r2.h ;
The second case occurs when a general instruction is combined with one or two memory references for joint issue. The latter portions are set off by a "||" token.
a0 = r3.h * r2.l || r1 = [p3++] || r4 = [i2++];
Multiple instructions can occur on the same line. Each must be terminated by a semicolon character.
Register Names
The assembler treats register names and instruction keywords in a case insensitive manner. User identifiers are case sensitive. Thus, R3.l, R3.L, r3.l and r3.L are all equivalent input to the assembler.
Register names are reserved and may not be used as program identifiers.
Some operations (such as "Move Register") require a register pair. Register pairs are always data registers and are denoted using a colon, eg., R3:2. The larger number must be written firsts. Note that the hardware only supports odd-even pairs, eg., R7:6, R5:4, R3:2, and R1:0.
Some instructions (such as –SP (Push Multiple)) require a group of adjacent registers. Adjacent registers are denoted in the syntax by the range enclosed in parentheses and separated by a colon, eg., (R7:3). Again, the larger number appears first.
Portions of a particular register may be individually specified. This is written with a dot (".") following the register name and then a letter denoting the desired portion. For 32-bit registers, ".H" denotes the most significant ("High") portion. ".L" denotes the least-significant portion. The subdivisions of the 40-bit registers are described later.
Accumulators
The set of 40-bit registers A1 and A0 that normally contain data that is being manipulated. Each accumulator can be accessed in four ways.
one 40-bit register
The register will be referred to as A1 or A0.
one 32-bit register
The registers are designated as A1.W or A0.W.
two 16-bit registers
The registers are designated as A1.H, A1.L, A0.H or A0.L.
one 8-bit register
The registers are designated as A1.X or A0.X for the bits that extend beyond bit 31.
Data Registers
The set of 32-bit registers (R0, R1, R2, R3, R4, R5, R6 and R7) that normally contain data for manipulation. These are abbreviated as D-register or Dreg. Data registers can be accessed as 32-bit registers or as two independent 16-bit registers. The least significant 16 bits of each register is called the "low" half and is designated with ".L" following the register name. The most significant 16 bits are called the "high" half and is designated with ".H" following the name.
R7.L, r2.h, r4.L, R0.H
Pointer Registers
The set of 32-bit registers (P0, P1, P2, P3, P4, P5, SP and FP) that normally contain byte addresses of data structures. These are abbreviated as P-register or Preg.
p2, p5, fp, sp
Stack Pointer SP
The stack pointer contains the 32-bit address of the last occupied byte location in the stack. The stack grows by decrementing the stack pointer.
Frame Pointer FP
The frame pointer contains the 32-bit address of the previous frame pointer in the stack. It is located at the top of a frame.
Loop Top
LT0 and LT1. These registers contain the 32-bit address of the top of a zero overhead loop.
Loop Count
LC0 and LC1. These registers contain the 32-bit counter of the zero overhead loop executions.
Loop Bottom
LB0 and LB1. These registers contain the 32-bit address of the bottom of a zero overhead loop.
Index Registers
The set of 32-bit registers (I0, I1, I2, I3) that normally contain byte addresses of data structures. Abbreviated I-register or Ireg.
Modify Registers
The set of 32-bit registers (M0, M1, M2, M3) that normally contain offset values that are added and subtracted to one of the index registers. Abbreviated as Mreg.
Length Registers
The set of 32-bit registers (L0, L1, L2, L3) that normally contain the length in bytes of the circular buffer. Abbreviated as Lreg. Clear the Lreg to disable circular addressing for the corresponding Ireg.
Base Registers
The set of 32-bit registers (B0, B1, B2, B3) that normally contain the base address in bytes of the circular buffer. Abbreviated as Breg.
Floating Point
The Blackfin family has no hardware floating point but the .float directive generates ieee floating point numbers for use with software floating point libraries.
Blackfin Opcodes
For detailed information on the Blackfin machine instruction set, see the Blackfin(r) Processor Instruction Set Reference.
Next: Blackfin Directives, Previous: Blackfin Options, Up: Blackfin-Dependent [Contents][Index]